头部Logo
Set Home |  Add to Favorites   中文简体
头部热线电话
Frequently Questions
 
More>>Recommended
 
latest announcement

3200User’s Guide
Release date:2015-11-02

electronic article surveillance

 

eas- 3200 digital eas

 

 

user’s guide

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

shuangbei nanjing technology co.,ltd

 

 

www.jseas.cn

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ι main technical parameters

 

 

  transmitter:

 

 

          power supply               dc 24v

 

 

          dc     source               <300ma

 

 

          safeguard                  250v, 0.5a fuse

 

 

          output current              180ma<jp1<240ma

 

 

          center frequency             8.2mhz ±0.05mhz

 

 

          scanning frequency bias          ±500khz

 

 

          scan rate                     180hz ± 1hz

 

 

receiver:

 

 

power supply                    dc 24v

 

 

dc source                        ______

 

 

in guard status                 <380ma

 

 

in alarm status                 <380ma

 

 

sensitivity                       5μa

 

 

safeguard                         250v, 0.5a, fuse

 

 

radio-frequency bandwidth           7.5mhz ~8.5mhz

 

 

ⅱ  mounting tools instruments and  meters

 

 

             name                    quantities        

 

 

1、earth groove cutter                1

 

 

2、bumping electric hammer            1

 

 

3、hand electrical drill              1

 

 

4、adjustable  wrench                 1

 

 

5、iron  hammer                       1

 

 

6、clipper                            1

 

 

7、bevel    pliers                    1

 

 

8、crosshead screwdriver              1

 

 

9、screwdriver for adjustment         1

 

 

10、universal   meter                 1     

 

 

 

 

 

ⅲ   environmental conditions

 

 

1、mounting position of eas detector

 

 

eas detector cannot be set up in the distance of 0.5m from a metal door or 1m from any metal objects inducing the metal wall reinforcements, goods shelves, metal showcases, hand purchasing carts, etc. it is also not allowed to mount this detector in 2m nearby the money machines, id devices for credit cards, telephones, computers, data cables, neon lamps, air conditioners, heaters, etc.

 

 

2、to ensure the eas operation reliability, at first it is necessary to detect the interference sources and set the system far away from these sources if they are difficult to be removed. generally, there are two kinds of interference: the first is active in nature such as the various electric sparks, motors, blowers and fire due to improper contact, or interferences caused by serious noises of power source; the second is passive in nature such as the conduct rolls, pos machine _disibledevent="font-size: 10.5pt; font-family: "arial","sans-serif"">

 

 

 

Previous:The Spring Festival holiday notice

Next:3600 motherboard explanations

 

Back HomeAbout UsFrequently QuestionsFeedbackLegal adviser
Links: 泽雷电子 | Electronic Article Surveillance | Electronic Article Surveillance | EAS website | E-Shop
网站ICP备案号:苏ICP备17025707号-1

Tel:+86-25-86896103  85127106 13327710987     Fax:+86-25-68696103-603  4008602755   Address:

Chinese Xuanwu District of Nanjing City No. 101

CopyRight © 2010 123456.com All Rights Reserved. 

 NanJing double north electronic Technology Co., LTD. All rights reserved